Operation Ruito wireless dental endo motor:Wireless dental endo motor is a root canal treatment equipment.  We supply more kinds of high quality wireless dental endo motor for you. Endodontic equipment from all the dental products with a great choice of Ruito endo motors, obturation units, and endodontic handpieces.  Welcome to contact us and get more specification.


Website:www.ruitodental.com
Email:ruito@ruitodental.com
Whatsapp:008613415719773

Friday, December 17, 2021

How to choose dental LED curing light?


www.ruitodental.com
ruitodental.com

When purchasing an dental LED light curing machine, you should pay attention to the problem of LED overheating and light intensity decreasing too fast with time. This is actually a heat problem of LED. In order to obtain the large light energy output of the LED, the driving current of the LED must be increased as much as possible, but if the driving current is too large, the LED will generate serious heat, which will greatly shorten the service life of the LED and even burn the LED. When purchasing, it can be tested from two aspects.

First, after working in continuous strong light mode for 10 seconds, touch the shell near the LED of the curing machine for a few seconds, so as not to feel hot. Of course, when testing the machine, you should avoid making the machine emit strong light for a long time in succession, so as to prevent the LED from overheating and being damaged.

Second is to test the change of light intensity over time, let the curing machine work in continuous strong light mode, the light intensity at the beginning of the test work and the light intensity at 10 seconds of work, the less the light intensity decreases, the better, the difference between the two It is appropriate not to exceed 10%.

Dental light curing generally consists of: the light curing lamp is composed of a handle, a charging base, a hood, an isolation sleeve, a test block, an optical lens, a power plug and a power adapter.

If you want to know more about dental light curing, please pay attention to RUITO dental equipment, where you can buy the best products at the lowest price.(www.ruitodental.com,whatsapp:008613415719773)


Friday, December 10, 2021

Does the dental X-ray machine have radiation?

In life, people are often exposed to large or small diseases. How do we go to the hospital to infer the diagnosis of the disease? There are no more than two ways: First, the doctor has observed and confirmed the cause of the disease after the patient's description. 2. Find out the cause of the disease through the images obtained by the X-ray film. Whenever some patients hear about taking X-rays, they will not only think "Is there radiation from X-rays?" Let’s find out today whether the radiation dose of X-ray machines will cause harm to the body.

The radiation dose of dental radiographs used in dental clinics is small, the radiation dose is about 5 microsieverts, and the radiation dose of chest radiographs is about 20 microsieverts. After all, how big is this radiation amount? Let's roughly estimate that each of us in this world is in radiation at all times. According to the International Commission on Radiological Protection, the radiation limit of the general population is not more than 5 millisieverts per person per year [(mSv), which is equivalent to 5000 microsieverts (uSv)]. Generally, the radiation dose that a person receives per year is about 4 millisieverts, which is a small dose and a safe dose. About 85% of the radiation comes from the environment in which we live (in nature), and only 15% comes from medical examinations. Even if you sleep in a bed with others, you will be exposed to radiation from the body of others, about 0.05 microsieverts. Even if you prefer independence, the annual radiation dose of potassium in your body is about 390 microsieverts.

In other words, the radiation dose of watching a computer, TV or mobile phone is about 1 microsievert a year. If you eat a banana, the radiation dose is about 0.1 microsievert. If you spend a day in a radiation area that is above the equilibrium level, such as the Qinghai-Tibet Plateau, the radiation dose is about 1.2 microsieverts. Estimated by smoking two packs of cigarettes a day, the radionuclide radiation dose in cigarette tobacco is equivalent to taking a chest X-ray once a day. So we don’t have to worry about the X-ray radiation taken in the hospital.

If want a quality dental x ray machine,please contact this:www.ruitodental.com/ Email:ruito@ruitodental.com/whatsapp:0086 13415719773

www.ruitodental.com
ruitodental.com


Monday, December 6, 2021

Dental handpiece maintenance steps

In oral treatment, the drainage dental handpiece is the most commonly used device, and the function and structure of the dental handpiece are complicated. Due to the many internal pipelines and cavities, the patient’s mouth, saliva, and various debris will splash and contaminate the phone during use. At the same time, the negative pressure generated when the operation is stopped will also enter the blood, saliva and debris. Inside the crumbs, suck back inside. If the dental handpiece is not cleaned thoroughly, the dirt retained in the interior of the dental handpiece, raw materials, etc., will become solid after being inactivated by high temperature, so the fouling matter will adhere to the tube wall, bearings and balls, etc., which will affect the performance of the dental handpiece. And lifespan, which will affect the effectiveness of the dental handpiece infection is a serious infection. This small class will explain in detail the cleaning and maintenance steps of the drainage dental handpiece.

Maintenance Step:

1. Remove the dental handpiece from the quick interface or cable, and remove the bur.
2. Remove the dental handpiece from the quick interface or cable, and remove the bur.
3. Take the cleaned dental handpiece out of the cleaning machine and dry its interior with a pressure air gun.
4. Connect the dental handpiece to the matching oil injection adapter or connector and insert it into the automatic oil injection maintenance machine for oil injection. Choose a suitable oiling program.
5. Pack the dental handpiece after oil injection.
6. Perform pressure steam sterilization on the dental handpiece.

FAQ:

Q: Why do dental handpieces need to be thoroughly cleaned before sterilization?
A: The dental handpiece enters the patient’s mouth directly and is in close contact with the saliva, blood, gingival crevicular fluid and dental plaque in the mouth. When the dental handpieces stops rotating, the air in the head of the dental handpieces is under negative pressure. This negative pressure can cause the saliva, blood, microorganisms, cutting debris and other pollutants in the patient's mouth to be sucked back into the dead corners and water and air ducts inside the dental handpieces. If it is not cleaned, the blood stains, grease stains and other dirt remaining in the internal cavities and gaps of the dental handpieces will be easier to form biofilms after high temperature and high pressure sterilization, thereby preventing effective contact between microorganisms and gases, causing sterilization failure.

Q: Can the oil injection curing machine replace the cleaning machine?
A: The important role of cleaning is to remove all visible dirt, tissues, blood stains and other organic matter to ensure the effect of sterilization. For dental handpieces that do not use a cleaning machine, the oil injection curing machine alone cannot effectively remove the dirt inside and outside of the dental handpieces and the microorganisms (film) on the pipe wall, so that the oil film of the oil injection curing machine cannot contact the dental handpieces well, and the dirt will accumulate more and more. As a result, cross-infection is caused, and the damage rate of dental handpieces will also increase.

Q: Can the dental handpieces that is not cleaned be directly sterilized by high temperature and high pressure? What is the result?
A: Studies have shown that it is easier to form a biofilm in the inner cavity of the dental handpieces if it is not cleaned. The time required for complete sterilization of the bacterial spores wrapped by the biofilm in a pressure steam environment at 134°C is 150 minutes. Three times of pre-vacuum sterilizer working time (3-4 minutes), the sterilization will not be complete, which will cause sterilization failure, thereby increasing the probability of subsequent infection of patients.