Thursday, February 17, 2022

Common questions about using dental endo motor and clinical attention for root canal preparation

Dental endo motor Root canal instruments are widely used in oral clinics. So the question is, what are the common questions when using the Dental endo motor?

A. Can Dental endo motor be used for any root canal treatment?

R. The curved and calcified root canal hand、machine combination is safer

A. The surgeon feels that the preparation speed is too slow?

R. 250-400rpm is the safest and most efficient speed for Nitinol

A. Is the torque smaller the better?

R. It is very important to limit the torque, a reasonable torque is the guarantee of cutting force

A. Is it possible to expand while measuring?

R. The main purpose of expanding while measuring is to prevent the expansion of the apical foramen. For conditions that cannot be accurately adapted to root measuring, the expanding while measuring cannot be used.

A. Can measuring and expanding at the same time replace the root canal measurement alone?

R. Root canal measurement is affected by a variety of environments, and root canal treatment should strictly follow the sequence of "establishing a straight path - root canal measurement - preparation" to prevent accidental risks

A. What kind of machine do users use to expand needles?

R. Generally speaking, any brand of nickel-titanium expansion system can be used, each with its own characteristics, which mainly depends on the cost-effectiveness and the familiarity of the doctor.

How to prevent broken endomotor root canal file

① To prevent endomotor root canal files breakage, the operator's experience is the key

1. Learning about the machine and endomotor root canal files allows you to reduce the risk of use;

a. Control the torque and speed It is best to set the torque control motor and the matching speed. Following the torque recommended by the endomotor root canal files manufacturer, speed is especially important for treatment safety.

b. Measure the length of the instrument each time it enters the root canal. Instruments that are too long increase the risk of torsional fracture. Equipped with root canal length measuring instrument, calipers, etc. for working length measurement.

2. The correct operation method is very important: do not pressurize and force the tip. The instruments cannot stay in the root canal for too long;

3. Instruments should be checked before surgery,

a. The fracture of instruments mostly occurs in molars, especially in small and narrow root canals such as the mesial root canals of upper and lower molars, and special care should be taken before treatment;

b. Curved root canals, re-treatment and calcified root canals require special requirements for instruments and manipulations, and it is best to use a new root canal files;

4. Establish a straight path to maintain an unobstructed root canal, pay attention to gestures during operation, and try to ensure that the enlargement root canal files and the root canal path are in a straight line to reduce the bending resistance of the enlargement root canal files at the crown and the stress on the instrument;

5. The root canal should be kept fully lubricated and should be flushed every time it is prepared;

6. Because the inside of the root canal is narrow, do not put pressure on the enlargement root canal files during operation, and the cutting should be done completely by the power of the machine itself and the sharp edge of the enlargement root canal files;

7. In the case of inexperience, it is safest to use the recommended minimum torque. In general, lower rotational speeds will extend the clinical life of the device and reduce the chance of breakage.

② Efficient and safe, excellent equipment is the guarantee

1. Nickel-titanium expansion requires both rotational speed and torque. Inappropriate rotational speed and overloaded torque are important factors for root canal files breakage.

2. Control the torque and speed Follow the torque recommended by the expanding root canal files manufacturer.

3. Measure the length of the instrument each time it enters the root canal. Equipped with root canal length measuring instrument, calipers and other tools for working length measurement.

③ Select and use the expanding root canal files

1. In addition to the difference in material and design, different endomotor root canal files are very knowledgeable, including the bonding of the blade spiral.
Familiar with the performance of nickel-titanium instruments, use methods and root canal preparation techniques. Such as: the endomotor root canal files of mature big brands, such as Protaper, profile, K3, etc., all advocate the use of root-oriented technology;

2. With the continuous update of nickel-titanium root canal instrument technology, the domestic enlarged needles have made great progress. The design and manufacture of nickel-titanium root canal enlargement root canal files with higher cutting efficiency, better forming ability, less stress and stronger fracture resistance have been improved in new materials and manufacturing processes. For example, the sc enlarged file has special channel file and open file. The system is 0.02 and 0.08 respectively, and its tip diameter is 15mm and 30mm, respectively. The special heat treatment process makes the nickel-titanium resistant to torsion and bending fatigue, and can rebound. Performance and life be greatly improved.

3. Choose and use the endomotor root canal files well, and control the number of times of use when using it: when using it, you should observe more whether there is wire drawing or deformation, and if you find it, you must discard it in time, otherwise you will regret it;

4. Taking SC-Pro as an example, it is recommended to have 25-30 root canals for anterior teeth and 1 or so root canals (or 5 posterior teeth) for posterior teeth. The preparation of sharply curved root canals will cause great damage to the instruments and is recommended for one-time use. After each use, it is best to record the number of uses to prevent the equipment from fatigue; the debris of the enlarged root canal files blade should be cleaned repeatedly and in time, and a cleaning table should be equipped.

Clinical treatment steps and precautions
① Requirements for opening the pulp hole (medullary cavity preparation):
removal of the entire medullary roof;
The wall of the pulp opening should be in line with the apex 1/3 of the root canal, and there is no resistance between the instrument and the wall of the coronal root canal;
Make the temporary sealing drug retain well;
Provide a space for the irrigation fluid to flow, and minimize the damage to the tooth tissue.
Steps: local anesthesia---adding the rubber dam---removing all the humus---removing the pulp top---forming a straight line with 1/3 of the root tip.
② Determination of root canal length

Be sure to have the exact working length before doing the apical 1/3 preparation.

(1) Subtract 2mm from the preoperative film as the estimated root canal length (IL)
(2) 06 or 08# file and pre-bend the tip to estimate the length of the root canal, prepare the root canal to the 10 or 15# file and enter the root canal, and feel stuck, if the root canal diameter is larger than 10 or 15 #File, you can directly select a file that can be held for diagnostic root length measurement.
(3) Parallel projection X-rays.
(4) WL=IL±d-1, + if the instrument is shorter than the root hole, - if the instrument exceeds the root hole.
(5) If the instrument is more than 4mm away from the root hole, the diagnostic wire photography should be readjusted.
(6) If the length of the diagnostic wire is adjusted with a root length measuring instrument before the diagnostic wire is used, the distance between the diagnostic wire and the apical foramen can be avoided.

③ Principles of root canal irrigation

Flushing should include the number of flushes, the amount of fluid to be flushed and the depth of flushing. Before root canal preparation, every file change, before trying the main gutta-percha and before sealing the medicine, it should be rinsed, and the amount of each rinse should be more than 1-2mm. The role of the rinse solution: rinse, disinfect, lubricate, dissolve organic matter, bleach. The most commonly used rinsing fluid is NaOCl. Root canal preparation must be done in moist conditions. The irrigator should be open on the side of the tip, and the irrigator should be loosely placed in the root canal. The mechanical flushing effect only occurs at the part where the flusher reaches, therefore, the flusher should be placed at a sufficient depth, and the flushing speed should not be too fast and the force should not be too large.

④Principles of root canal preparation

Before the root tip 1/3 is prepared, the working length must be accurate; the root canal must be kept moist during root canal preparation to ensure adequate irrigation; the root canal file should not be skipped; the root canal file should be pre-bent; the minimum expansion of the root apex is 25 #, easy to fill; according to the difference of the initial filing, the MAF of each tooth is different, generally 2-3 sizes larger than the initial filing. If the MAF is less than 60#, a 4mm retreat preparation should be done, 1mm each time. If the MAF is greater than 60, it should go back and expand by 2. Preparation of the coronal 2/3: The purpose is to provide sufficient access for the lateral compression device to reach the apical region. The lateral pressure device should be able to reach the apex of 2 mm, otherwise it will not be able to form a good apical sealing effect. GG BUR 2# should reach no less than 6mm apex, or 2/3 of the working length, GG BUR 3# is 2-3mm shorter than GG BUR 2#. Reconditioning of the root canal wall: The MAF file is pre-bent to the working degree to make the root canal wall smooth. Check the taper of the root canal preparation with a lateral pressure. The lateral pressure device corresponding to the MAF should be able to freely reach 1-2 mm from the apex; the apical stenosis is obvious and there is a clear stop (STOP); no debris is deposited within a few mm of the apical area; the root canal wall is smooth without Step; 2/3 taper of root canal crown is sufficient, greater than the taper of gutta percha and the corresponding taper of lateral pressure

⑤ Notes on root canal filling

Root canal filling methods: cold lateral pressure, hot lateral pressure, vertical pressure.
Choice of main gutta-percha tip: freely enter 1-2mm from the apex and feel tight (TUGBACK); consistent with or slightly larger than the prepared MAF; within 0.5mm of the working length; in the apical stenosis blocked.

Notes for root filling: The root filling paste should be applied only to the root canal wall; the paste should be applied using a paper twist or a file equivalent to MAF; the tip of the main gutta-percha dipped in paste is inserted to the working length; the lateral pressure device should be able to reach The distance from the working length is 1-2mm; generally, only 2-3 auxiliary tips with the same taper as the lateral pressure device are recommended; if the main apex is found to be short or over 2mm on the postoperative apical radiograph, it should be refilled.

Problems in root canal preparation

(1) Loss of working length

Causes: root canal blockage, shoulder formation, instrument breakage, accumulation of dentin debris in the apical area, etc.

The precautionary principle: reference point fixation

Fixed stopper position

Pre-bent all root canal files

Note that the curve of the root canal file should be consistent with the curve of the root canal

The X-ray projection angle should be consistent

Preservation of root canal preparation

Repeated use of small files to open the root canal (recapitulation)

Prepare root canals one by one.

(2) Root canal blockage:

Causes: dentin debris, filling material blocking the apical area, etc.

Preventive principle: remove carious tissue and unbase glaze before pulp opening

The root canal orifice should be adequately prepared;

Rinse extensively to remove debris;

The root canal file should be cleaned when it enters the root canal again;

The root canal file cannot be skipped;

Repeated use of small files to open the root canal (recapitulation);

Do not over-rotate or force the file;

Do not prepare root canals in dry conditions;

Temporary seal perfect;

Treatment method: try 15#K file or expander to pass the blockage
The tip of the 10#K file is bent 3-4mm into a 45-degree angle, and it is rotated along the circumference of the blockage to find the feeling of being stuck (catch). blockage. And according to X-ray to determine. EDTA helps.

If the blocked part cannot pass, it should be prepared to the blocked part, and root filling should be done, and regular observation; the root tip can also be plasticized, and the root filling can also be plasticized. Root surgery if necessary.

(3) Ledging and shoulder passing:

Reason: root canal file has no pre-bending, shoulder formation, etc.

Change the file too fast, skip the number.

Prevention of Shoulder Formation: Preparatory Steps for Small, Curved, Calcified Root Canals

exact working length

The medullary cavity is filled with NaOCl

Pre-bend 06#, 08# and 10# root canal files, and gradually reach the working length. Use the step-by-step root canal file preparation method and 1-3mm short strokes (in-and-out strokes).

The shoulder can be removed if detected early, but it is more difficult to remove the shoulder produced by the 25# or 30# file. The method is the same as through the root canal blockage.

(4) The method of breaking and taking out the instrument:

prevention:

① Replace the new file in time:

② After the root canal file reaches the working length, you can only do the file action, 1-3mm pulling; do not rotate

Use of H file: H file can only be used for lifting in loose root canals.

Treatment: The instrument is broken at the root canal orifice, and the instrument can be exposed for 2mm along the periphery of the instrument with a small bur, and taken out with a small blood vessel forceps.

The instrument is broken deep in the root canal, and the ultrasonic method is used.

If the broken instrument is firmly stuck in the root canal, apical surgery should be performed. The broken instrument is closely combined with the dentin of the root canal wall, and the prognosis is good. If the broken instrument is loose in the root canal or out of the apical foramen, surgery should be performed.

(5) Changes in the position of the apical foramen (zipping, transposition, transportation)

Reason: The root canal file was not pre-bent, and the preparation device for the root canal curve was too large and too hard.

Appearance: teardrop

Prevention: pre-curve root canal file; prepare in the opposite direction of curvature (anticurvature filing).

Treatment: teardrop-shaped formation, which can be filled by various methods; if the apical foramen is displaced and perforated, a paste containing Ca(OH)2 should be used; elbow-shaped structure formation (elbow) is best to use vertical compression method root Charge. Radical surgery should be performed if treatment fails.

(6) Insufficient or excessive root canal preparation

Problems and countermeasures in root canal filling

(1) The main gutta percha tip cannot reach the working length

Cause: dentin debris clogging the apical area;

shoulder formation;

Insufficient taper or poor continuity of the root canal;

Artificial root canal formation or straightening of curved root canals, loss of working length;

The gutta-percha tip is too large or the taper is not standard.

Treatment method: The main file is used to prepare the root canal again to reach the apical area, and each file should be properly pre-bent; diagnostic wire photography is used to determine the problem; a lot of rinsing to remove the blockage; after the root canal is re-prepared and dried, the main file should be used again to determine The apical area is well prepared.

(2) The main gutta-percha tip has no tightness

Reason: The apical area is prepared at 25-40#, sometimes it is difficult to feel tightness, and it is easy to feel tightness above 40#;

The taper of the main gutta-percha tip is poor, and the main gutta-percha tip is too small;

Discontinuous taper of root canal preparation, displacement and deformation of the apical foramen;

dentin debris remains in the root canal;

Treatment method: Change the taper of the tip of the main gutta-percha tip

The use of gutta percha (GP gauge): the too-fine gutta percha tip must have a diameter hole one size larger than the gutta percha gauge, and cut off 0.5-1mm.

(3) The root filling in the apical area is not dense

Reasons: The apical area is not patency or the taper is insufficient, and the lateral pressure device cannot reach the apex;

The auxiliary gutta-percha tip is not dipped in root filling paste, the auxiliary gutta-percha tip is not long enough to reach the depth reached by the lateral pressure device, or the tip is curved;

Side pressure is too large;

Too much root filling paste;

Excessive accumulation of dentin debris in the apical area (1-3mm)





Monday, January 24, 2022

Tips for buying a dental handpiece


With more and more brands of dental handpieces on the market, everyone is dazzled. Each manufacturer has the key points and selling points of publicity, making it difficult to know where to start when purchasing dental handpieces. Faced with so many choices, how to choose Where to buy?
RUITO DENTAL EQUIPMENT COMPANY will give you some advice. First of all, when buying a dental handpieces, you must pay attention to the following four basic principles:
Several properties affecting cross-infection control
1. Safety performance
1). Whether the dental handpieces material selection and surface coating can withstand high temperature and high pressure disinfection above 135 degrees. Inferior metal or dental handpieces with poor coating process, the surface will be damaged after repeated high temperature and high pressure sterilization, which will affect the hand feel and not beautiful when used.
2). Whether the machine head has an anti-suction design: The anti-suction design is actually a precise one-way valve. Its function is like the valve in the heart or blood vessel, which only allows water to flow out, but cannot be sucked back. In this way, cross-infection caused by back suction can be effectively avoided. Even with the strict sterilization of the handpiece, there is still a risk of contamination in the lines of the dental unit! Anti-suction device can effectively prevent such pollution!
3). Whether it can accept professional hot cleaning: In developed countries, hot cleaning has long been included in the standard for disinfection and cleaning of oral instruments. Hot cleaning will greatly reduce the chance of people coming into direct contact with contaminated dental handpieces and will eventually become mainstream. Therefore, a good dental handpieces must be able to withstand the high pressure hot water flow in the thermal washer.
4. Whether there is a built-in filter: Advanced dental handpieces bearings are very precise, so the requirements for water quality are also higher. A replaceable built-in filter will be designed in the entry pipe of the dental handpieces to purify the water source.
A key feature that affects the safety of treatment: the cooling device of the dental handpieces
Every dental handpieces must have a spray, but it is not necessarily whether it has cooling in place. If the pulp is thermally damaged due to poor cooling, which leads to pulp lesions after tooth preparation, it will be troublesome. Moreover, there is often no reason for this complication. Because, there is no problem in operation? Pay attention when purchasing:
How many holes is the dental handpieces spray? The best is of course four-hole spray, with more cooling, even if there is a problem with one hole, the other holes can still ensure the cooling effect. But the dental handpieces with a porous spray is much more expensive than a single-hole spray. Where is the spray point on the head of the dental handpieces? Where does the spray reach the bur? The direction of the spray is very important. A good dental handpieces requires the spray to be stable and accurate, so as to ensure that the water mist gathers on the cutting point and achieves the cooling effect.(There is a good quality but reasonable price of Ruito dental handpieces,welcome to contact us to get price)
2. Work efficiency
1).The power of the dental handpieces: the greater the power, the greater the torque, and the displacement of the root car is similar, so there is no need to explain it.
2). The coating material on the surface of the dental handpieces and the anti-slip design: This is very important to the hand feel, whether it is comfortable to hold in your hand, you can only make a choice after you have experienced it yourself.
3). The weight of the dental handpieces and the pipeline is evenly distributed, and the position of the gravity balance point: the center of gravity is not good either.
4). The angle between the head and the fuselage: the angle has a great influence on the operation, especially for patients with limited posterior teeth and openings, improper angle will make the work difficult and the field of vision is unclear.
5). Dental handpieces noise: the quieter the better, everyone knows it.
6). Dental handpieces fiber brightness: it is best to be close to natural light. 25000LUX
7). Whether it is a quick-connect interface: the advantages of quick-connect connectors are many, but they are expensive.
8). Whether it is a push-type chuck: The thimble-type chuck is not as convenient as the push-type chuck, but the clamping force of some brands of push-type chucks is not enough, so be careful.
9). Dental handpieces maintenance materials and methods: This is the most easily overlooked issue. Many people buy a good dental handpieces, but they do not maintain it, which seriously affects the performance of the dental handpieces.

3. Service life

This is performance that everyone is concerned about. If there are frequent problems with the dental handpieces, which affects work efficiency and affects work mood, the following points determine the service life: brand and place of origin: the brand is very important, and the place of origin is also very important. The same brand may produce different things in different places. Everyone knows that big manufacturers build factories all over the place, but their core technologies may still be reserved. Therefore, it is best to buy a dental handpieces from a big brand and the original factory. Bearing material and process: First of all, look at the brand, ceramic bearings are generally better than steel ball bearings, but inferior ceramic bearings are not as good as good brand steel ball bearings.(Ruio dental handpice used for imported ball ceramic bearing with long working life)
The material and craftsmanship of the internal pipeline of the dental handpieces: This is invisible to ordinary people. If you purchase in large quantities, you can let the manufacturer show the internal structure.
4. Cost of use
Cost control is a very professional thing. A lot of statistical work needs to be done. For clinics, calculating the cost of a dental handpieces should not only look at its unit price, but should carefully calculate its usage, maintenance costs, etc., and make a comprehensive assessment. It is better to have more detailed records and analysis to find out the most critical factors that affect the cost and make improvements, rather than blindly buying low-priced products. Low-priced products only reduce the cost of purchase, but not necessarily effectively reduce the cost of use.
The simplified algorithm of the second is: ABC algorithm
A: The unit price of the dental handpieces
B: Maintenance cost: mainly maintenance oil
C: Number of uses: only approximate estimates, of course, it is better to record each time. Usage cost=(A+B)/C
I believe that everyone should pay attention to the following four basic principles when purchasing a dental handpieces, and also know how to choose a suitable dental handpiece in the future. For clinics with a large workload, you also need to calculate the doctor’s labor cost. If the doctor’s time It is very valuable, and it is also worth considering if you choose a high-end dental handpieces to save effective time.

Monday, January 3, 2022

How to use dental LED curing light?

Dentist Dental LED Curing Light wire type, directly connect with dental unit to use. built-in lamp curing unit inside without battery it is easy for all the ways shipping. environmental plastic shell green and black 2 colors to choose. 1.5 meter silica material long wire enough for the dentist to operate. At the same time, better antioxidant and longer service life. the LED curing light for dental use 5W high power LED, 12mm high permeability glass fiber-optic light guide. There with 3 working modes of operation strong, flashing and gradually strong, the light intensity between 1200 to 2000 mw/cm² suitable for all brands of resin materials. About the working time can be adjusted to 5-40s. for the small packing to save more space in the shipment. Main unit of the dentist dental LED curing light with 2 years warranty. We are the manufacturer majoring in producing LED curing lights from 2010 to now already 11 years.  Stable quality, reasonable price and the efficient delivery speed of the curing light are popular with customers both at home and abroad. Mass or small orders are welcome, meanwhile the OEM service is available also.

Specification:

item:value Input

Voltage :110V- 240V AC/50-60hz

Lithium battery voltage :DC 4.2V

LED Light Power :5W

Battery Output Voltage :DC3.6V /2200mAh

Single package size :23X17.2X5.3 cm

Lithium battery capacity 1400mAh

Solidify time and depth 5S / 3 mm

Light wavelength 420-480nm

Light intensity 1200-2000mw/cm2

Weight 0.57kg 


Welcome to contract us!

www.ruitodental.com

whatsapp:008613415719773

Email:ruito@ruitodental.com 

Tuesday, December 28, 2021

Operation Ruito wireless dental endo motor

Operation Ruito wireless dental endo motor:Wireless dental endo motor is a root canal treatment equipment.  We supply more kinds of high quality wireless dental endo motor for you. Endodontic equipment from all the dental products with a great choice of Ruito endo motors, obturation units, and endodontic handpieces.  Welcome to contact us and get more specification.


Website:www.ruitodental.com
Email:ruito@ruitodental.com
Whatsapp:008613415719773

Friday, December 17, 2021

How to choose dental LED curing light?


www.ruitodental.com
ruitodental.com

When purchasing an dental LED light curing machine, you should pay attention to the problem of LED overheating and light intensity decreasing too fast with time. This is actually a heat problem of LED. In order to obtain the large light energy output of the LED, the driving current of the LED must be increased as much as possible, but if the driving current is too large, the LED will generate serious heat, which will greatly shorten the service life of the LED and even burn the LED. When purchasing, it can be tested from two aspects.

First, after working in continuous strong light mode for 10 seconds, touch the shell near the LED of the curing machine for a few seconds, so as not to feel hot. Of course, when testing the machine, you should avoid making the machine emit strong light for a long time in succession, so as to prevent the LED from overheating and being damaged.

Second is to test the change of light intensity over time, let the curing machine work in continuous strong light mode, the light intensity at the beginning of the test work and the light intensity at 10 seconds of work, the less the light intensity decreases, the better, the difference between the two It is appropriate not to exceed 10%.

Dental light curing generally consists of: the light curing lamp is composed of a handle, a charging base, a hood, an isolation sleeve, a test block, an optical lens, a power plug and a power adapter.

If you want to know more about dental light curing, please pay attention to RUITO dental equipment, where you can buy the best products at the lowest price.(www.ruitodental.com,whatsapp:008613415719773)


Friday, December 10, 2021

Does the dental X-ray machine have radiation?

In life, people are often exposed to large or small diseases. How do we go to the hospital to infer the diagnosis of the disease? There are no more than two ways: First, the doctor has observed and confirmed the cause of the disease after the patient's description. 2. Find out the cause of the disease through the images obtained by the X-ray film. Whenever some patients hear about taking X-rays, they will not only think "Is there radiation from X-rays?" Let’s find out today whether the radiation dose of X-ray machines will cause harm to the body.

The radiation dose of dental radiographs used in dental clinics is small, the radiation dose is about 5 microsieverts, and the radiation dose of chest radiographs is about 20 microsieverts. After all, how big is this radiation amount? Let's roughly estimate that each of us in this world is in radiation at all times. According to the International Commission on Radiological Protection, the radiation limit of the general population is not more than 5 millisieverts per person per year [(mSv), which is equivalent to 5000 microsieverts (uSv)]. Generally, the radiation dose that a person receives per year is about 4 millisieverts, which is a small dose and a safe dose. About 85% of the radiation comes from the environment in which we live (in nature), and only 15% comes from medical examinations. Even if you sleep in a bed with others, you will be exposed to radiation from the body of others, about 0.05 microsieverts. Even if you prefer independence, the annual radiation dose of potassium in your body is about 390 microsieverts.

In other words, the radiation dose of watching a computer, TV or mobile phone is about 1 microsievert a year. If you eat a banana, the radiation dose is about 0.1 microsievert. If you spend a day in a radiation area that is above the equilibrium level, such as the Qinghai-Tibet Plateau, the radiation dose is about 1.2 microsieverts. Estimated by smoking two packs of cigarettes a day, the radionuclide radiation dose in cigarette tobacco is equivalent to taking a chest X-ray once a day. So we don’t have to worry about the X-ray radiation taken in the hospital.

If want a quality dental x ray machine,please contact this:www.ruitodental.com/ Email:ruito@ruitodental.com/whatsapp:0086 13415719773

www.ruitodental.com
ruitodental.com


Monday, December 6, 2021

Dental handpiece maintenance steps

In oral treatment, the drainage dental handpiece is the most commonly used device, and the function and structure of the dental handpiece are complicated. Due to the many internal pipelines and cavities, the patient’s mouth, saliva, and various debris will splash and contaminate the phone during use. At the same time, the negative pressure generated when the operation is stopped will also enter the blood, saliva and debris. Inside the crumbs, suck back inside. If the dental handpiece is not cleaned thoroughly, the dirt retained in the interior of the dental handpiece, raw materials, etc., will become solid after being inactivated by high temperature, so the fouling matter will adhere to the tube wall, bearings and balls, etc., which will affect the performance of the dental handpiece. And lifespan, which will affect the effectiveness of the dental handpiece infection is a serious infection. This small class will explain in detail the cleaning and maintenance steps of the drainage dental handpiece.

Maintenance Step:

1. Remove the dental handpiece from the quick interface or cable, and remove the bur.
2. Remove the dental handpiece from the quick interface or cable, and remove the bur.
3. Take the cleaned dental handpiece out of the cleaning machine and dry its interior with a pressure air gun.
4. Connect the dental handpiece to the matching oil injection adapter or connector and insert it into the automatic oil injection maintenance machine for oil injection. Choose a suitable oiling program.
5. Pack the dental handpiece after oil injection.
6. Perform pressure steam sterilization on the dental handpiece.

FAQ:

Q: Why do dental handpieces need to be thoroughly cleaned before sterilization?
A: The dental handpiece enters the patient’s mouth directly and is in close contact with the saliva, blood, gingival crevicular fluid and dental plaque in the mouth. When the dental handpieces stops rotating, the air in the head of the dental handpieces is under negative pressure. This negative pressure can cause the saliva, blood, microorganisms, cutting debris and other pollutants in the patient's mouth to be sucked back into the dead corners and water and air ducts inside the dental handpieces. If it is not cleaned, the blood stains, grease stains and other dirt remaining in the internal cavities and gaps of the dental handpieces will be easier to form biofilms after high temperature and high pressure sterilization, thereby preventing effective contact between microorganisms and gases, causing sterilization failure.

Q: Can the oil injection curing machine replace the cleaning machine?
A: The important role of cleaning is to remove all visible dirt, tissues, blood stains and other organic matter to ensure the effect of sterilization. For dental handpieces that do not use a cleaning machine, the oil injection curing machine alone cannot effectively remove the dirt inside and outside of the dental handpieces and the microorganisms (film) on the pipe wall, so that the oil film of the oil injection curing machine cannot contact the dental handpieces well, and the dirt will accumulate more and more. As a result, cross-infection is caused, and the damage rate of dental handpieces will also increase.

Q: Can the dental handpieces that is not cleaned be directly sterilized by high temperature and high pressure? What is the result?
A: Studies have shown that it is easier to form a biofilm in the inner cavity of the dental handpieces if it is not cleaned. The time required for complete sterilization of the bacterial spores wrapped by the biofilm in a pressure steam environment at 134°C is 150 minutes. Three times of pre-vacuum sterilizer working time (3-4 minutes), the sterilization will not be complete, which will cause sterilization failure, thereby increasing the probability of subsequent infection of patients.

If have any questions,welcome to contact us:ruito@ruitodental.com / www.ruitodental.com

www.ruitodental.com
Ruito dental handpieces