Thursday, August 18, 2022

The structure of the dental handpiece

Dental handpieces are classified into two types: ball bearing type and air bearing type, according to the different working methods of the bearings used.

Ball bearing type high-speed handpiece is mainly composed of handpiece, handle and dental handpiece connector.

1. The internal structure of the machine head

The vortex core rotor is the core component of the machine head. It is composed of a bearing, a wind wheel and a mandrel. There are upper and lower miniature bearings in the machine head. The bearing is cushioned with an O-shaped rubber ring to keep the bur at high speed. Radial and axial concentricity during rotation, and reduces operating noise and vibration.

2. Clamping method of bur

There are various ways for the machine head to clamp the bur. In the early days, the reed-type clamp was used, that is, there were 3 evenly divided bow-shaped reeds in the mandrel. The bur handle is inserted into it, and the reed is deformed by force to clamp the needle handle.

Nowadays, screw-type and pressing-type bur clamping methods are mostly used. The clamping sleeve of this dental handpiece has an elastic three-lobed clamping spring. The clamping spring is in the shape of a hammer and has three axial grooves. Or press the top spring to open or lock the clamp spring to hold the bur.

3. Spray structure

There is a water pipe and a gas pipe at the tail of the turbine dental handpiece. The water and gas are mixed at the outlet of the handpiece and sprayed out from the spray hole in the form of a mist.

4. Dental handpiece connector

The dental handpiece connector is the connection between the handpiece and the output hose of the main unit. The main air flow that drives the rotation of the dental handpiece wind wheel and the branch air that generates atomization enter the main air hole, branch hole and water hole of the dental handpiece connector through the pipeline respectively. Dental handpiece. There are two ways of connection between the handpiece and the handpiece connector: one is with a fixed lock nut on the handpiece connector, and the other is with a quick-release connector.

RUITO dental equipment company offer all kinds of dental handpiece with good price,if want to know more,please check the website:www.ruitodental.com.



Monday, May 23, 2022

Use of dental implanter and maintenance of implant motor



Dental Implant Motor Features:

1) Intuitive LCD display and control panel bring convenience to the operation;

2) Original imported brushless motor is characterized by great torque, low noise, non-vibrations as well as accuracy;

3) Alternative input supply voltage: AC100-110V or AC220-240V;

4) Multifunctional foot switch is not only handy to operate but also against cross-infection caused by the contact between hands and the device;

5) Adjustable rotation speed, torque, coolant flow and forward/reverse, which can meet various demands during implanting process;

6) 10 types of reduction contra angles are able to be selected in order to meet various clinical demands;

7) 10 kinds of program settings. Each of which allows setting up different values ​​of rotation speed, torque, coolant flow, forward/ reverse and reduction ratio.

Specification:

Power Supply: AC100-110V or AC220-240V 50/60HZ

Conductivity Detection Range: 210W

Motor Rotation Speed ​​Range :1000rpm-30000rpm (1:1)

Torque Range: 5.0-55N.cm (20:1)

Coolant Flow: 0-100ml/min

Stored Programs: 10 types

Foot Switch: Control coolant flow, program forward/reverse, speed





Maintenance of control unit and foot switch:

When wiping off the blood or normal saline on the control unit and the foot switch, please unplug the power cord first, wipe it off with a cloth soaked in water (after wringing it out), and then carefully wipe it with a cloth containing disinfectant alcohol go.

Automatic protection circuit:

When the motor is overloaded, in order to protect the motor and the control host, the protection circuit starts to activate, and the power supply to the motor is automatically cut off.

How to release the protection circuit

Release and then step on the foot switch to release the action of the protection circuit.

Replace the fuse:

If the voltage is abnormal, plug in the power supply and start the machine, but the machine does not respond, please check the fuse.

How to replace the fuse? Please use a tool to pry open the fuse box on the back of the control host, pull out the old fuse, and replace it with a new one. 

How to maintain the dental handpiece:

After each treatment, rotate the handpiece of the handpiece in clean water for 4-5 seconds to wash off the attached blood and saline. If there is too much dirt attached to the body of the dental handpiece, wash it with water and wipe it off with a dry soft cloth. Do not fully immerse the handpiece in water to prevent water from entering the handpiece from the rear of the handpiece.

Specific operations:

After each operation,

1. Wipe the surface of the dental handpiece with 75% alcohol gauze.

2. Then replace the salt water with distilled water, and run the motor to rinse the inside of the dental handpiece.

3. Disassemble the dental handpiece and soak it in a special disinfectant solution for 10~15min. Alcohol and hydrogen peroxide are prohibited.

4. Scrub the blood stains with a soft brush, place it in an ultrasonic vibration cleaning machine, pay attention to separating it with a rubber pad, and finally ultrasonically clean it with distilled water
5. Oil injection lubrication
Lubricate the thoroughly cleaned and dry parts separately for assembly.
Use of dental implant: used for perforation of jaw bone or implant drilling during oral implant treatment.

Indications for dental implants:

1.Patients with missing one tooth, multiple teeth, or all teeth.
2.The alveolus of the mandibular full mouth is completely absorbed, it is difficult to wear traditional full mouth dentures, the function is not good, and it is difficult to wear them securely.
3.Those who wear traditional removable dentures with poor fixation and cannot tolerate non-functional mucous membranes.
4.Those who have special requirements for the appearance and function of dentures.
5.There is a problem with the remaining teeth around the missing teeth, and traditional dentures cannot be used.

Prohibited items:

1.Be sure to replace the bur or attach and detach the dental handpiece after the rotation of the motor has completely stopped. (May cause injury.)

2.After the treatment, please clean it immediately, lubricate it with oil (do not lubricate the motor with oil), and sterilize it at high temperature and high pressure. (May cause blood to clot inside the dental handpiece.)

3.In the environment of electromagnetic waves, malfunction may occur. Do not place this product near machines that generate electromagnetic waves.



Dental endo motor with apex locator operate video

Updated 5 working models NEW R-Smart Plus dental endo motor with apex locator

Feature
Six Functions;
German Motor;
Large Colorful OLED Screen;
Four Working Modes;
R-Smart Plus New Apex Locator with Endo Motor.

 

Technical Data
Battery: 7.2V/1400mAh
Adapter: 100V~240V 0.8A 50Hz/60Hz
Revolving speed: 200~600rpm
Torsion: 0.6~4.0N.cm
Dimensions: 250mm*210mm*140mm
Buzzer alert: The buzzer will alert when the file is less than 2mm closed to the apex




www.ruitodental.com

Email:ruito@ruitodental.com 

Tuesday, May 17, 2022

How to Find The Best Dental Equipment Dental Handpiece

Are you looking for good, cheap dental equipment? Do you want to find a full range of dental equipment?

www.ruitodental.com
#dentalequipment 
#dentalequipmentsupplier
#dentalequipmentmanufacturer

Monday, May 16, 2022

Here's a video on how to install a dental X-ray machine sensor.

High quality portable dental HDR intraoral X-ray sensor dental imaging plate scanner dental


X ray sensor Professional High Technology : CMOS detector technology with CSI scintillator Ensures optimal resolution Low dose clinical imaging AED Technology : Automatic exposure detection,Fast imaging,easy workflow compatible with different x ray generators. High-speed Direct USB interface Easy to connect to PCs without needing an additional control box Ergonomic Design : Rounded corner,smooth edges,flexible cable Untra-slim Design : 4.4mm sensor,enables maximum patient comfort Multi-languages: Covenient for dentists in different countries and regions. Specification: Theoretical Resolution    25lp/mm True Resolution   20lp/mm Pixel Matrix   1000*1500 Active Area(mm)   20*30 Mechanical Size(mm)   25.4*36.8*4.4 Data interface   USB 2.0 AD Conversion(bit)   16 Protection   IP68  Air pressure : 860hPa~1060hPa;


Monday, April 18, 2022

Maintenance of Dental Autoclave Sterilizer

Sterilizer is an instrument that can kill or remove all microorganisms on the transmission medium, including bacterial spores and non-pathogenic microorganisms. There are usually three methods: moist heat sterilization, dry heat sterilization, and chemical sterilization.

The Dental Autoclave Sterilizer consists of a water tank, a sterilization chamber, a thermal insulation layer, a door body, a pipeline system, a control system and an outer casing. The sterilizer should have a 121°C or 134°C setting program. The sterilization temperature should not exceed the set temperature of 4 °C; the temperature difference between any two points should not exceed 2 °C; the performance of other products should meet the technical requirements of registered products. Doing good maintenance and maintenance is actually the best way to prolong the life of each instrument and reduce the incidence of failures. There is no shortage of sterilizers. After all, long-term sterilization of sterilizers is also necessary. Better maintenance and maintenance are required.

1. Daily maintenance
1.1 Scrub the exterior of the sterilizer and keep the sterilization chamber clean and dry every day
1.2 Cleaning of the filter screen, the filter screen is easily attached to various fiber debris and sediments, which will seriously affect the speed of vacuuming and the smoothness of condensed water treatment
1.3 Check whether the rubber ring is damaged or not and whether the air inlet is blocked. It is best to apply talcum powder on the rubber strip after using it every day to prolong the service life of the rubber strip.
1.4 Check whether the pointer of the pressure gauge can return to "0", and the degree is not accurate
1.5 After the sterilization work is over, cut off the power supply, turn off the power supply, and turn off the steam power supply.

2. Regular maintenance:
2.1 Clean the inner wall of the sterilization pot with neutral detergent every week; remove the remaining water inside the boiler and close the valve in time
2.2 Pull the handle of the safety valve in the inner chamber of the sterilizer once a month and flush it with steam to prevent its action from malfunctioning. At the same time, it should be noted that the sterilization room must be thoroughly descaled, repaired and maintained at least once a month. When descaling, properly mix water and descaling agent according to the principle of 1:100, and then perform descaling after mixing evenly. After 10 minutes, clean the container and then wipe the container with a lint-free cloth to keep the container dry. The sterilization room and the cleaning car can also be cleaned according to the above method, and the stainless steel parts should be wiped with gauze soaked in paraffin oil.
2.3 Every quarter, let the pressure sterilizer manufacturer carry out large-scale maintenance and repair work on the instrument. For example, check whether the door panel of the autoclave is flat, and remove the cover panel in the autoclave. At the same time, rust should be removed for the rusted parts, and high temperature lubricating oil should be added to the pressure sterilizer.
2.4 Remove the sealing strip every half a year, clean it with soapy liquid, wipe it with alcohol and dry it, and then put it back into the sealing tank; descale the steam generator; clean the air inlet and water inlet pipe filters; And steam generator pressure gauge sent to the Measurement Technology Testing Institute for testing and retain the test certificate.
2.5 The sterilizer and the safety valve of the steam generator are sent to the Special Equipment Supervision and Inspection Institute for inspection once a year and the inspection report is retained.

Whether it is daily maintenance or regular maintenance, it is an opportunity for the instrument to rejuvenate. In the day-to-day work, it can also feel a refreshing maintenance, which can not only prolong the service life, but also stabilize the way it works.  ----From Ruito dental equipment
Website:www.ruitodental.com